Search results for "Ph measurement"

showing 3 items of 3 documents

Chlorides concentration and ph measurement of concrete structure through immersed sensors

2016

The present work develops non-destructive measurements of chemical-physical parameters of concrete, in order to evaluate the degradation condition and to monitor, in time, the aging process. This study in particular focuses on the measurement of parameters such as pH, and therefore the carbonatation level of the concrete, and salt concentration (i.e. chlorides), and the evolution of these quantities with time. The analysis can be extended to other chemical-physical parameter of interests for which is provided a specific microsensor.

CHLORIDES CONCENTRATION pH MEASUREMENTS
researchProduct

Physicochemical stability of carfilzomib (Kyprolis®) containing solutions in glass vials, ready-to-administer plastic syringes and infusion bags over…

2017

Centralized aseptic preparation of ready-to-administer carfilzomib containing parenteral solutions in plastic syringes and polyolefine (PO) infusion bags needs profound knowledge about the physicochemical stability in order to determine the beyond-use-date of the preparations. Therefore, the purpose of this study was to determine the physicochemical stability of carfilzomib solution marketed as Kyprolis® powder for solution for infusion. Reconstituted solutions and ready-to-administer preparations of Kyprolis® stored under refrigeration (2–8℃) or at room temperature (25℃) were analyzed at predetermined intervals over a maximum storage period of 28 days. Chemical stability of carfilzomib wa…

Chromatographybusiness.industryInfusion solutionPh measurementCarfilzomibVial03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOncologychemistry030220 oncology & carcinogenesisMedicinePharmacology (medical)Aseptic processingbusinessParenteral solutions030215 immunologyJournal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners
researchProduct

pH of multipurpose contact lens solutions over time

1998

The pH of nine different brands of multipurpose contact lens solutions available in Spain was determined over a period of 32 days after opening the bottles. Five bottles of nine solutions were used, each of which was buffered and obtained from different manufacturers. The pH measurements were taken using a micropH 2002 Crison pH-meter (accuracy +/- 0.001 pH units). Each solution was measured three times daily over the test period using 10-ml samples taken from the same container. Fluctuations in pH over time were observed but these were within the range of ocular comfort. The average pH of all the solutions tested proved to be between 6.99 and 7.56.

Contact lensOphthalmologyContact lens solutionsChromatographyMaterials scienceGeneral MedicinePh measurementOptometryBiomedical engineeringContact Lens and Anterior Eye
researchProduct